Operation Manual
![]()
Size:Download
SMT2200 - APC Smart-UPS 2200VA LCD 120V. UL Certificate for Smart-UPS 750/2200/3000VA LCD 120V and Smart-UPS 3000 RM 2U LCD 208V (Version 0) Add to My. A good user manual. The rules should oblige the seller to give the purchaser an operating instrucion of APC Smart-UPS 2200, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract.
Uninterruptible Power Supply
Low Voltage
SMX2000RMLV2U
SMX2200RMLV2U
SMX3000RMLV2U
SMX3000RMLV2UNC
SMX3000RMJ2U
High Voltage
SMX2200RMHV2U
SMX3000RMHV2U
SMX3000RMHV2UNC
Overview
About the UPS
The APC® by Schneider Electric
The
Safety
Read the Safety Guide included in the package before installing the UPS.
Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage.
Recycle the packaging.
Heavy: The external battery packs (XLBPs) are heavy. Always install the XLBPs at the bottom of the rack. Install the UPS above the installed XLBPs.
Product Overview
Front panel
Battery
Battery connectorDisplay interfaceBezel
Rear panel
Apc Smart Ups 2200 Tower Manual
Specifications
Operating Conditions
This unit is intended for indoor use only. Select a location sturdy enough to support the weight of the UPS and XLBP.
Do not operate the unit where there is excessive dust, or the temperature or humidity are outside the specified limits.
This unit has front and rear air vents. Allow adequate space for proper ventilation.
Environmental Specifications
Environmental factors impact battery life. High temperatures, poor utility power, and frequent, short duration discharges will shorten battery life.
For additional specifications, see the APC Web site at www.apc.com.
Operating 0° to 40° C (32° to 104° F)Temperature Storage
charge UPS battery every six months
Installation
UPS
For UPS installation information, see the
Network Management Card
For installation information, see the user manual provided with the Network Management Card (NMC). The user manual is also available on the APC Web site at www.apc.com.
External Battery Pack
For installation information, see the
Operation
Connect Equipment to the UPS
Note: The UPS will charge to 90% capacity in the first three hours of normal operation.Do not expect full battery runtime capability during this initial charge period.
1.Connect equipment to the outlets on the rear panel of the UPS.
2.Connect the UPS to the building utility power. Connect the UPS to a
3.Press the ON/OFF button on the front panel of the UPS to power the unit and all connected equipment.
4.To use the UPS as a master on/off switch, turn on all the equipment that is connected to the UPS.
See “Switched Outlet Groups” on page 11 for information on how to use the Switched Outlet Groups.
su0475a
Basic Connections
Serial port: Connect to a computer to use power management software, use the serial cable included with the unit.
USB port: Connect to a computer to use power management software.
Note: Serial and USB communication can only be used individually, they cannot communicate at the same time.
External Battery Pack connector: Connect XLBPs to provide extended runtime during power outages. The UPS can support up to 10 external battery packs.
Ground Screw: The UPS features a ground screw for connecting the ground leads on transient voltage devices. Prior to connecting a ground lead, disconnect the UPS from utility power.
Apc Smart Ups 2200 User Manual
Display Interface
Overview
Online LED
UPS Output On/Off buttonOn Battery LED
Apc Smart Ups Srt 2200 Manual
Fault LED
Replace Battery LEDDisplay screen
![]()
UPand DOWNbuttonsENTERbutton
ESCAPE button
Using the display interface
Use the UP andDOWN buttons to scroll through the main menu options. PressENTER to view the
Menu Overview
The
Note: Actual menu screens may differ by model.
Apc 2200 Manual
Configuration
Control
Test & Diagnostics
Statistics
Logs
Configuration
Smart Ups 2200 Rack Mount Manual
UPS Settings
Use the display interface to configure these settings at initial
Note: The unit will not turn on until all of these settings are entered.
High Voltage: 230 V • 200
Apc Smart Ups 2200 Tower Manual Pdf
•208
•220
•230
•240
Next >= Page 1 =12